ThinkStation BMC remote management
console
User Guide
First Edition (April 2024)
© Copyright Lenovo 2024.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services
Administration “GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-
35F-05925.
Contents
About this guide . . . . . . . . . . . . . iii
Chapter 1. Introduction . . . . . . . . . 1
Web browser requirements . . . . . . . . . . . 1
BMC management console standard level
features . . . . . . . . . . . . . . . . . . . 1
BMC startup . . . . . . . . . . . . . . . . . 1
Chapter 2. Access the BMC remote
management console web interface . . 3
Log in to the BMC remote management console
web interface. . . . . . . . . . . . . . . . . 3
Web interface introduction . . . . . . . . . . . 4
Chapter 3. Monitor your computer . . . 9
Dashboard. . . . . . . . . . . . . . . . . . 9
Sensor . . . . . . . . . . . . . . . . . . . 9
System Inventory . . . . . . . . . . . . . . 10
FRU Information . . . . . . . . . . . . . . 10
Chapter 4. Basic configurations . . . 11
Logs and Reports . . . . . . . . . . . . . . 11
Views . . . . . . . . . . . . . . . . . . . 11
Settings . . . . . . . . . . . . . . . . . . 12
Date & Time . . . . . . . . . . . . . . 13
Active Directory . . . . . . . . . . . . . 13
LDAP/E-Directory . . . . . . . . . . . . 15
RADIUS Settings . . . . . . . . . . . . 17
Log Settings . . . . . . . . . . . . . . 18
PAM Order Settings . . . . . . . . . . . 19
Event Filters . . . . . . . . . . . . . . 19
Alert Policies . . . . . . . . . . . . . . 20
LAN Destinations . . . . . . . . . . . . 21
Services . . . . . . . . . . . . . . . . 22
SMTP Settings . . . . . . . . . . . . . 23
SSL Settings . . . . . . . . . . . . . . 24
Security IP/User Block . . . . . . . . . . 25
Add Firewall Settings . . . . . . . . . . . 25
Add New IP Rule . . . . . . . . . . . . 25
Add New Port Rule. . . . . . . . . . . . 26
User Management . . . . . . . . . . . . 26
IPMI Interfaces . . . . . . . . . . . . . 29
Power Control . . . . . . . . . . . . . . . 29
Chapter 5. Advanced
configurations . . . . . . . . . . . . . 31
Network Settings . . . . . . . . . . . . . . 31
Network IP Settings . . . . . . . . . . . 31
Network Bond Configuration . . . . . . . . 31
Network Link Configuration . . . . . . . . 32
DNS Configuration . . . . . . . . . . . . 32
Sideband Interface (NC-SI) . . . . . . . . 33
Video Recording . . . . . . . . . . . . . . 33
Auto Video Trigger Settings . . . . . . . . 33
Auto Video Remote Storage . . . . . . . . 34
Auto Pre-Event Video Recordings . . . . . . 34
SOL Trigger Settings . . . . . . . . . . . 35
SOL Log Settings . . . . . . . . . . . . 35
SOL Configurations . . . . . . . . . . . 36
Remote Control . . . . . . . . . . . . . . . 36
KVM Mouse Settings . . . . . . . . . . . 36
Remote Session . . . . . . . . . . . . . 36
Remote Control . . . . . . . . . . . . . 37
Image Redirection . . . . . . . . . . . . . . 50
Media Redirection General Settings . . . . . 50
VMedia Instance Settings . . . . . . . . . 50
Active Redirections . . . . . . . . . . . 51
Local Images . . . . . . . . . . . . . . 51
Remote Images . . . . . . . . . . . . . 52
Maintenance . . . . . . . . . . . . . . . . 52
Backup Configuration . . . . . . . . . . 52
BMC Recovery . . . . . . . . . . . . . 53
Firmware Image Location . . . . . . . . . 53
Firmware Information . . . . . . . . . . . 53
Firmware Update . . . . . . . . . . . . 54
Preserve Configuration . . . . . . . . . . 55
Restore Configuration . . . . . . . . . . 56
Restore Factory Defaults . . . . . . . . . 56
System Administrator. . . . . . . . . . . 57
Appendix A. Trademarks . . . . . . . 59
© Copyright Lenovo 2024 i
ii ThinkStation BMC remote management console User Guide
About this guide
Before starting your tour, please read the following information:
Use this information to understand the notices that are used in this document.
Note: These notices provide important tips, guidance, or advice.
Warning: These notices provide information or advice that might help you avoid inconvenient or problem
situations.
Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is
placed just before the instruction or situation in which damage might occur.
Illustrations and user interface instructions in this documentation might look different from your product.
Documentation content is subject to change without notice. To get the latest documentation, go to
https://
support.lenovo.com/docs/bmc_web_guide
© Copyright Lenovo 2024 iii
iv ThinkStation BMC remote management console User Guide
Chapter 1. Introduction
This document explains how to configure the BMC (baseboard management controller) card settings on the
ThinkStation® BMC remote management console. The BMC remote management console works with UEFI
(Unified Extensible Firmware Interface) BIOS (Basic Input/ Output System) to provide systems-management
capability for ThinkStation computers.
The BMC remote management console is a new generation management controller for ThinkStation
computers. It consolidates the service processor functionality, video controller, and remote presence
capabilities into the BMC card installed on the ThinkStation computer system board. It provides the following
functions:
Choice of a dedicated or shared Ethernet connection for systems management (based on system support)
Support for HTML5
Remote configuration using BMC remote management console
Capability for applications and tools to access the BMC management console either locally or remotely
Enhanced remote-presence capabilities
Web browser requirements
ThinkStation BMC remote management console web interface supports one of the following web browsers:
Chrome latest version
Edge
Firefox
Safari (on MAC)
BMC management console standard level features
The following is a list of BMC management console standard level features:
Monitor your computer
Basic configurations
Advanced configurations
BMC startup
It takes about 2-3 minutes for BMC to start up. During the startup period, different products might have
different prompts. You can refer to each product’s User Guide for details.
Note: If you install the BMC card by yourself, make sure it is compatible with your ThinkStation and follow
the installation instructions provided in each product’s User Guide. Additionally, you need to update the
BIOS and EC firmware on your ThinkStation to the latest versions.
© Copyright Lenovo 2024 1
2 ThinkStation BMC remote management console User Guide
Chapter 2. Access the BMC remote management console web
interface
This chapter describes the setting up network connection and login procedures.
Log in to the BMC remote management console web interface
1. Ensure that the BMC card is correctly installed in your ThinkStation computer, and the Ethernet cable is
connected to the Ethernet connector on the BMC card.
2. Ensure that the management computer and client computers are in the same local area network.
3. Obtain the dynamic MAC IP address (eg: 10.176.7.xxx) from either client BIOS or router port management
interface.
4. Open the Web browser on the management computer and enter the login address (eg: https://10.176.7.
xxx/#login) to enter the remote management console login interface.
5. For initial access, input your username (default: admin) and password (default: admin), and click Sign me
in to enter the remote management console Web interface.
Warning: Once you log in to the application, it is recommended not to use the following options:
Refresh button of the Web browser
Refresh menu of the Web browser
Back and Forward options of the Web browser
F5 on the keyboard
Backspace on the keyboard
© Copyright Lenovo 2024 3
Notes:
Username must be a combination of 1 to 16 alpha-numeric characters and start with an alphabetical
character. It is case-sensitive and special characters like “-”(hyphen), “_”(underscore), and “@”(at
sign) are allowed.
When you log in using the username and password, you obtain full administrative rights. Password
change is required after the first log in. The new password must have a minimum of 10 characters and
contain characters from three of the following four categories:
English uppercase characters A-Z
English lowercase characters a-z
Digits 0-9
Special characters (!, $, #, %, etc.)
One-time password (OTP) mechanism is used to generate a temporary password. To use this
function, configure administrator’s e-mail ID in Settings SMTP Settings and user’s email ID in
Settings User Management. If you forget your password, click I forgot my password in the login
page to generate OTP that will be sent from administrator’s email to the previously configured user’s
email. This temporary password will be valid for only 5 minutes.
Do not use the same usernames for various authentication methods like AD, LDAP, RADIUS, or IPMI
since the privilege of one authentication method is overwritten by another authentication method
when you log in and hence the correct privilege cannot be returned properly.
Do not use the same usernames for various channels in IPMI.
6. Set the Web browser to accept file download when prompted. Ensure that JavaScript and cookies are
enabled for the login address.
Web interface introduction
After logging in successfully, the user information and quick buttons are displayed at the top and the
configurable menu is displayed on the left of the interface. The table below provides the name of each quick
button and its corresponding description:
Quick button name
Description
Message
Click to view the event log alert messages. Click the message to go to
the Logs and Reports page.
Notification Click to view the notification received.
Language
Click the drop-down list box to choose the language you prefer.
BIOS Click to view the AMI Remote BIOS Setup. The required username
and password are the same with those of the BMC Login.
Sync Click to synchronize with the latest Sensor and Event Log updates.
Refresh Click to reload the current page.
User There are five kinds of privileges.
Administrator: All BMC commands are allowed.
Operator: All BMC commands are allowed except for the
configuration commands that can change the behavior of the out-
of-hand interfaces.
User: Only valid commands are allowed.
OEM: All OEM commands are allowed.
No Access: Login access denied.
4 ThinkStation BMC remote management console User Guide
Quick button name Description
Sign out Click to log out of the ThinkStation BMC GUI.
Help Click the Help icon on each menu page to view more detailed
descriptions.
The table below provides the name of each menu and its corresponding description:
Menu name Description
Dashboard Provide the overall information about the status of a device.
Sensor Provide the relevant information of all sensors.
System Inventory Provide the components’ inventories of the device, including the
details of system, processor, memory controller, baseboard, power,
thermal, PCIE function and storage.
FRU Information Provide the BMC’s FRU device information.
Logs & Reports
IPMI Event Log
Audit Log
Video Log
SOL Log
Captured BSOD
Capture Log
HW Diagnostic Log (Available for some Thinkstation products)
Views
View SSL certificate
Existing Firewall Settings
Existing IP Rules
Existing Port Rules
Chapter 2. Access the BMC remote management console web interface 5
Menu name Description
Settings
Date & Time
Active Directory
LDAP/E-Directory
RADIUS Settings
Log Settings
PAM Order Settings
Event Filters
Alert Policies
LAN Destinations
Services
SMTP Settings
SSL Settings
Security IP/User Block
Add Firewall Settings
Add New IP Rule
Add New Port Rule
User Management
IPMI Interfaces
Network Settings
Network IP Settings
Network Bond Configuration
Network Link Configuration
DNS Configuration
Sideband Interface (NC-SI)
Video Recording
Auto Video Trigger Settings
Auto Video Remote Storage
Auto Pre-event Video Recordings
SOL Trigger Settings
SOL Log Settings
SOL Configurations
Remote Control
KVM Mouse Setting
Remote Session
Remote Control
Image Redirection
Media Redirection General Settings
VMedia Instance Settings
Active Redirections
Local Images
Remote Images
6 ThinkStation BMC remote management console User Guide
Menu name Description
Power Control View and control the power of your computer.
Maintenance
Backup Configuration
BMC Recovery
Firmware Image Location
Firmware Information
Firmware Update
Preserve Configuration
Restore Configuration
Restore Factory Defaults
System Administrator
Chapter 2. Access the BMC remote management console web interface 7
8 ThinkStation BMC remote management console User Guide
Chapter 3. Monitor your computer
BMC helps you to view and monitor information for the computers that you are accessing.
Dashboard
The Dashboard page provides the overall information about the status of a device.
Function Description
Firmware Information Display the version and build time of the BMC firmware.
Network Information Display the network details of the device. Click Edit to configure the
network.
Remote Control Click Launch JViewer to download a jviewer.jnlp file. Then, you can
launch the Remote Control page by clicking the jviewer.jnlp.
Note: Before you use this function, a JRE is needed to be installed
and configured. Moreover, the BMC’s IP is needed to add to the
Security’ Exception Site List in Java Control Panel to avoid the
application being blocked by java security.
Sensor Monitoring
Display the sensors’ information of the device. Click
to check the
sensor details.
Event Log
Display the event logs of the device logged by BMC.
Sensor
The Sensor page provides the relevant information of all sensors. This page shows the live readings for all the
available sensors with details like sensor name, status, current reading and behavior. Click on any sensor to
show more information, including thresholds and a graphical representation of all associated events.
© Copyright Lenovo 2024 9
Sensor state Description
Critical Select a sensor from the critical sensors list to view more details such
as sensor information and sensor events. Click Change Thresholds
to configure threshold settings.
Notes:
The threshold settings will be enabled only for administrator or
operator privilege users. For other users, the threshold settings
option will be disabled, and they can’t access to perform this
action.
The threshold value can only be changed if it has an initiate value.
You cannot change a threshold value if its initial value is set to NA.
The modified threshold value will be restored to the default value
after a BMC reset.
Normal Select a sensor from the normal sensors list to view more details such
as sensor information and sensor events. Click Change Thresholds
to configure threshold settings.
Notes:
The threshold settings will be enabled only for administrator or
operator privilege users. For other users, the threshold settings
option will be disabled, and they can’t access to perform this
action.
The threshold value can only be changed if it has an initiate value.
You cannot change a threshold value if its initial value is set to NA.
The modified threshold value will be restored to the default value
after a BMC reset.
Disabled A list of disabled sensors is displayed.
Discrete Sensor States Click System Event Log to view all the event entries for the selected
sensor in a reverse chronological order.
Notes: The typical state value of System Event Log is as follows:
0x8000: Normal
0x8004: SEL Log Area Reset/Cleared
0x8010: SEL Full
0x8020: SEL Almost Full, this event represents the SEL has
reached a point of being 75% or more full.
System Inventory
The System Inventory page provides the inventory information of the host machine, including the details of
System, Processor, Memory Controller, Baseboard, Power, Thermal, PCIE Function and Storage. Select any
component to view the details of the component.
FRU Information
The FRU Information page displays product information for the BMC’s FRU devices.
Sensor type
Description
Available FRU Devices Select a FRU Device ID from the drop-down list box to view the
details of the device.
Product Information Product information in details.
10 ThinkStation BMC remote management console User Guide
Chapter 4. Basic configurations
Logs and Reports
The Logs & Reports page enables you to view various event logs statistics and use different filter options to
view those specific events. You also can clear or download the event logs.
Log type Description
IPMI Event Log Display the list of events incurred by different sensors on this device.
Click on a record to see the details of that entry. Click the statistical
graph to view the number of events by date. You can use the date
range, sensor type, or sensor name filter options to view those
specific events.
Audit Log
Display audit events for this device (if configured).
Note: For configuration, go to Settings Log Settings
Advanced Log Settings.
Video Log
Display available recorded video files (if the options have been
configured).
Notes:
For configuration, go to Video Recording Auto Video Trigger
Settings.
You can play or download the video only if file size is lesser than 40
MB. Browsers have various memory restrictions, due to this
browser cannot store and process data greater than 40MB
(approximately). If file size is greater than 40 MB, user will be
notified with a message to use Java player Application.
SOL Log Display the list of available recorded video files.
Notes:
For configuration, go to Video Recording SOL Trigger
Settings.
By default, video files will be stored in the local path of the BMC. If
the remote video support is enabled, then the video files will be
stored only in the remote path, and not within the BMC.
Captured BSOD Display a snapshot of the blue screen captured if the host system
crashed since the last reboot.
Note: KVM service should be enabled to display the BSOD screen.
For KVM Service configuration, go to Settings Services KVM.
Captured Log Download the logs captured by the BMC.
HW Diagnostic Log
Show and download the hardware diagnostic logs if host supports
this feature.
Views
The Views page enables you to view the following information:
© Copyright Lenovo 2024 11
View content Description
View SSL Certificate View the basic information about the uploaded SSL certificate in
readable format.
Certificate Version
Serial Number
Signature Algorithm
Public Key
Issuer Common Name (CN)
Issuer Organization(O)
Issuer Organization Unit (OU)
Issuer City or Locality(L)
Issuer State or Province (ST)
Issuer Country(C)
Issuer E-mail Address
Valid From
Valid Till
Existing Firewall Settings Click the Existing Firewall Settings block to view the existing firewall
settings details. If no firewall settings exist, click Settings Add
Firewall Settings to add a new firewall setting.
Existing IP Rules
Click the Existing IP Rules block to view the existing IP rules details.
If no IP rules exist, click Settings Add New IP Rule to add a new IP
rule.
Existing Port Rules
Click the Existing Port Rules block to view the existing port rules
details. If no port rules exist, click Settings Add New Port Rule to
add a new port rule.
Port Single (or) Range Start: To configure the port or range of
port Addresses.
Port Range End: To configure the port or range of port addresses.
Protocol: This field specifies the protocols for the configured port
or port ranges.
Network Type: This field specifies the affected network type for
the particular port or port ranges.
Enable Timeout: To enable or disable firewall rules with timeout.
Start Date: The respective firewall rule effect will start from this
time.
Start Time: The respective firewall rule will start from this time.
End Date: The respective firewall rule effect will end on this date.
End Time: The respective firewall rule will end at this time.
Rule: To indicate Allow or Block status.
Delete: To delete the entry to the firewall rules list.
Settings
The Settings page enables you to access various configuration settings.
12
ThinkStation BMC remote management console User Guide
Date & Time
Set the date and time on the BMC.
Settings name Description
Configure Date & Time Display time zone list containing the UTC offset along with the
locations and Navigational line to select the location which can be
used to display the exact local time.
Select Time Zone Set the date and time on the BMC.
Note: If the time zone is selected as Manual Offset, the map
selection will be disabled. The time zone settings will be reflected only
after saving the settings.
Automatic NTP Date & Time
Automatically synchronize date and time with the NTP Server.
Primary NTP Server: To configure a primary NTP server to use
when automatically setting the date and time.
Secondary NTP Server: To configure a secondary NTP server to
use when automatically setting the date and time.
Note: The secondary NTP server is an optional field. If the primary
NTP server is not working, then try the secondary NTP Server.
Automatic PTP Date & Time Automatically synchronize date and time with the PTP Server.
Active Directory
Store information and data about networks and domains. It also helps to organize these objects for easy
retrieval and access, allows access by end users and administrators and allows the administrator to set
security up for the directory.
Chapter 4. Basic configurations 13
Settings name Description
Active Directory General Settings To configure Active Directory General Settings:
1. Click Active Directory General Settings to open the Active
Directory General Settings page.
2. Check or clear the Enable Active directory Authentication
check box to enable or disable Active Directory Authentication
respectively.
3. Specify the Secret username and password in the Secret
Username and Secret Password fields respectively.
Notes:
Secret username or password for AD is not mandatory. When
secret username or password is empty, authentication fails will
be always treated as invalid password error. For invalid
password error, PAM will not try other authentication methods.
It is recommended to keep AD in the last location in PAM
order.
Username is a string of 1 to 64 alphanumeric characters. It
must be case sensitive and start with an alphabetical
character. Special characters like comma, period, colon,
semicolon, slash, backslash, square brackets, angle brackets,
pipe, equal, plus, asterisk, question mark, ampersand, double
quotes, space are not allowed.
Password must be at least 6 characters long and no longer
than 127 characters. Space is not allowed.
4. Specify the Domain Name for the user in the User Domain Name
field. For example, MyDomain.com.
5. Configure IP addresses in Domain Controller Server Address1,
Domain Controller Server Address2, and Domain Controller
Server Address3.
Notes: At least one Domain Controller Server Address must be
configured.
IP Address is made of 4 numbers separated by dots as in
“xxx.xxx.xxx.xxx”.
Each number ranges from 0 to 255.
First number must not be 0.
Domain Controller Server Addresses will support IPv4 Address
format and IPv6 Address format.
6. Click Save to save your settings and return to the Active
Directory Settings page.
Active Directory Role Groups Display any configured role groups and the available slots. You can
modify, add or delete role groups. Group domain can be the AD
domain or a trusted domain. Group name should correspond to the
name of an actual AD group.
Notes:
To view the page, you must be at least a user.
To modify or add a group, you must be an administrator.
To add a new role group:
1. Select a role group and click on the blank area to open the Role
Groups page.
14 ThinkStation BMC remote management console User Guide
Settings name Description
2. Enter the group name, group domain, and group privilege in
corresponding fields.
Notes:
Role group name is a string of 64 alpha-numeric characters.
Special symbols such as hyphen and underscore are allowed.
Domain name is a string of 255 alpha-numeric characters.
Special symbols such as hyphen, underscore, and dot are
allowed.
3. Select KVM Access or VMedia Access.
4. Click Save to add the new role group and return to the Role
Group list.
LDAP/E-Directory
LDAP is an Internet protocol that ThinkStation BMC card can use to authenticate users. If you have an LDAP
server configured on your network, you can use it as an easy way to add, manage and authenticate
ThinkStation BMC card users. This is done by passing login requests to your LDAP Server. This means that
there is no need to define an additional authentication mechanism, when using the ThinkStation BMC card.
Since your existing LDAP Server keeps an authentication centralized, you will always know who is accessing
the network resources and can easily define the user or group-based policies to control access.
Chapter 4. Basic configurations 15
Settings name Description
LDAP/E-Directory General Settings To configure LDAP/E-Directory General Settings:
1. Click Settings LDAP/E-Directory LDAP/E-Directory
General Settings to open the LDAP/E-Directory Settings page.
2. Check Enable LDAP/E-Directory Authentication to enable
LDAP/E-Directory Settings.
Note: During login prompt, use username to log in as an LDAP
group member.
3. Select the encryption type for LDAP/E-Directory from the
Encryption Type.
Note: Configure proper port number when SSL is enabled.
4. Select the Common Name Type as IP Address.
5. Enter the IP address of LDAP server in the Server Address field.
Notes:
IP Address is made of 4 numbers separated by dots as in ‘xxx.
xxx.xxx.xxx’.
Each number ranges from 0 to 255 and the first number must
not be 0.
IPv4 and IPv6 address format is supported.
Configure FQDN address when using StartTLS with FQDN.
6. Specify the LDAP Port in the Port field.
Note: The default port is 389. For SSL connections, the default
port is 636. The port value ranges from 1 to 65535.
7. Specify the Bind DN that is used during bind operation, which
authenticates the client to the server.
Notes:
Bind DN is a string of 4 to 64 alpha-numeric characters, and it
must start with an alphabetical character.
Special symbols like dot (.), comma (,), hyphen (-), underscore
(_), and equal-to (=) are allowed. For example: cn=manager, ou=
login, dc=domain, dc=com.
8. Enter the password in the Password field.
Notes:
Password must be at least 1 character long and space is not
allowed.
This field will not allow more than 48 characters.
9. Enter the Search Base. The Search base allows the LDAP server
to find which part of the external directory tree to be searched.
The search base may be something equivalent to the
organization, group of external directories.
Notes:
Search base is a string of 4 to 63 alpha-numeric characters,
and it must start with an alphabetical character.
Special symbols like dot (.), comma (,), hyphen (-), underscore
(_), and equal-to (=) are allowed. For example: ou=login, dc=
domain, dc=com.
16 ThinkStation BMC remote management console User Guide
Settings name Description
10. Select Attribute of User Login to find the LDAP/E-Directory
server which attribute should be used to identify the user.
Note: It only supports cn or uid.
11. Select CA Certificate File from the field to identify the certificate
of the trusted CA certs.
12. Select the Certificate File to find the client certificate filename.
13. Select Private Key to find the client private key filename.
Note: All the 3 files are required when StartTLS is enabled.
14. Click Save to save the settings.
LDAP/E-Directory Role Groups
To add a new role group:
1. Select a role group and click on the blank area to open the Role
Groups page.
2. Enter the group name, group domain, and group privilege in
corresponding fields.
Notes:
Role group name is a string of 255 alpha-numeric characters.
Special symbols such as hyphen and underscore are allowed.
Role group domain name is a string of 4 to 64 alpha-numeric
characters, and it must start with an alphabetical character.
Special symbols like dot (.), comma (,), hyphen (-), underscore
(_), and equal-to (=) are allowed. For example: cn=manager, ou=
login, dc=domain, dc=com.
3. Select KVM Access or VMedia Access, or both.
4. Click Save to add the new role group and return to the Role
Group list.
RADIUS Settings
RADIUS is a modular, high performance and feature-rich RADIUS suite including server, clients,
development libraries and numerous additional RADIUS related utilities. This menu is used to set the RADIUS
Authentication.
Chapter 4. Basic configurations 17
Settings name Description
RADIUS General Settings To configure Radius:
1. Check Enable RADIUS Authentication to authenticate the
RADIUS.
2. Enter the IP address of RADIUS server in Server Address.
Notes:
IP Address (Both IPv4 and IPv6 format).
FQDN (Fully Qualified Domain Name) format.
3. Enter the RADIUS port number in Port.
Note: The default port is 1812 and port value ranges from 1 to
65535.
4. Enter the authentication secret of RADIUS server in Secret.
Notes:
This field will not allow more than 31 characters.
Secret must be at least 4 characters long and space is not
allowed.
5. Select KVM Access, VMedia Access, or both.
6. Click Save to save the RADIUS General Settings.
RADIUS Advanced Settings To configure the Radius Authorization:
1. Check Enable RADIUS Authentication to enable the RADIUS to
authenticate.
2. Click RADIUS Advanced Settings to open the Radius
Authorization window. For authorization purpose, configure the
Radius user with Vendor Specific Attribute in Server side.
Example 1:
test admin Auth-Type := PAP
Cleartext-Password:=”admin”
Auth-Type := PAP
Vendor-Specific = “H=4”
Example 2:
test operator Auth-Type := PAP
Cleartext-Password:=“operator”
Auth-Type := PAP
Vendor-Specific = “H=3”
If you change the Vendor-Specific value in server then you should
change the same values in this page.
3. Click Save to save the configurations.
Log Settings
Display a list of system logs and audit logs occurred in this device.
18
ThinkStation BMC remote management console User Guide
Settings name Description
SEL Log Settings Policy To configure the log policy for the event log:
Log Policy: To enable or disable the Linear Storage Policy or
Circular Storage Policy.
Save: To save the configured settings.
Advanced Log Settings To configure the advanced log:
1. In the Audit Log field, check or clear the Enable option as
desired.
2. Click Save to save the configurations.
PAM Order Settings
Configure the PAM ordering for user authentication into the BMC.
To configure PAM ordering:
1. Select the required PAM module and click and drag the required PAM module. It can be moved UP or
DOWN to change its arrangement order.
2. Click Save to save the configurations.
Notes:
It is recommended not to keep the same username for different PAM modules.
If Authentication fails, the reason of failure could be invalid user or invalid password.
If Radius Authentication fails, we can’t differentiate whether it is invalid user or invalid password. So it
is always treated as invalid username error and PAM will try other authentication methods.
If AD contains secret username and password as empty, Authentication failures will be always treated
as invalid password error. For invalid password error, PAM will not try other authentication methods.
So, it is recommended to keep AD in the last location in PAM order.
Whenever the configuration is modified, the web server will be restarted automatically. Logged-in
session will be logged out.
Event Filters
Platform Event Filter (PEF) provides a mechanism for configuring the BMC to take selected actions on event
messages that it receives or has internally generated. These actions include operations such as system
power-off, system reset, as well as triggering the generation of an alert. This menu contains pre-configured
40 events with PEF IDs.
To configure event filters:
1. Click the Event Filters section to configure the event filters in the available slots.
2. To add an event filter entry, select a free section to open the event filter entry page.
Settings name
Description
Enable this filter Check this option to enable the PEF settings.
Event Severity to trigger Select any one of the Event severities from the list.
Event Filter Action Alert It is checked by default. This action enables PEF Alert action (read
only).
Power Action Select any option from the drop-down list box.
Chapter 4. Basic configurations 19
Settings name Description
Alert Policy Group Number Choose any one of the configured group numbers from the drop-
down list box.
Note: Alert Policy must be configured under Settings Alert
Policy.
Raw Data Check this option to fill the Generator ID with raw data.
Generator ID 1
Used to give raw generator ID1 data value.
Generator ID 2
Used to give raw generator ID2 data value.
Note: In RAW Data field, specify hexadecimal value prefix with
‘0x’.
Generator Type Choose the event generator as Slave Address if event was
generated from IPMB. Otherwise as System Software ID if event
was generated from system software.
Slave Address/Software ID Specify corresponding I2C Slave Address or System Software ID.
Channel Number Choose the particular Channel Number that event message was
received over. Or choose ‘0’ if the event message was received via
the system interface, primary IPMB, or internally generated by the
BMC.
IPMB Device LUN
Choose the corresponding IPMB Device LUN if events generated
by IPMB.
Sensor Type Select the Sensor Type of sensor that will trigger the event filter
action.
Sensor name Choose the particular sensor from the sensor list.
Event Options Choose Event Options to be either All Events or Sensor Specific
Events.
Event Trigger
Used to give Event/Reading type value.
Note: Value ranges from 1 to 255.
Event Data 1 AND Mask Used to indicate wildcarded or compared bits.
Note: Value ranges from 0 to 255.
Event Data 1 Compare 1 and Event Data 1
Compare 2
Used to indicate whether each bit position’s comparison is an
exact comparison or not.
Note: Value ranges from 0 to 255.
Event Data 2 AND Mask
Similar to Event Data 1 AND Mask.
Event Data 2 Compare 1 and Event Data 2
Compare 2
Similar to Event Data 1 Compare 1 and Event Data 1 Compare 2
respectively.
Event Data 3 AND Mask
Similar to Event Data 1 AND Mask.
Event Data 3 Compare 1 and Event Data 3
Compare 2
Similar to Event Data 1 Compare 1 and Event Data 1 Compare 2
respectively.
3. Click Save to save the configurations and return to event filter list.
4. Click Delete to delete the existing filter.
Alert Policies
Configure the alert policy for the PEF configuration. You can add, delete or modify an entry in this page.
To configure alert policies:
20
ThinkStation BMC remote management console User Guide
1. Click the slot for which you must configure the alert policy. For example, if you have chosen Alert Policy
Group Number as 4, you have to configure the 4th slot (the slot with Policy Number 4) in the Alert Policy
page.
2. Select Policy Group Number from the drop-down list box.
3. Check Enable this alert to enable the policy settings.
4. Select any of the Policy Action from the drop-down list box.
5. Select a particular LAN Channel from the available channel list.
6. In the Destination Selector field, select a particular destination from the configured destination list.
Note: LAN Destination must be configured under Settings LAN Destinations. That is, if you select
the number 4 for destination selector in Alert Policy Entry page, then you must configure the 4th slot
(LAN Destination Number 4) in the LAN Destinations page.
7. Check Event Specific Alert String, if the Alert policy entry is Event Specific.
8. In the Alert String Key field, select any one value that is used to look up the Alert String to send for this
Alert Policy entry.
Note: Using Web UI, Alert strings cannot be configured but option for Event Specific alert strings can be
enabled or disabled. There is an option to select only the alert string keys, but alert strings must be
configured using IPMI Command (Set PEF Config Parameter as “Alert String”).
9. Click Save to save the new alert policy and return to Alert Policy list.
10. Click Delete to delete a configuration.
LAN Destinations
Used to configure the LAN Destination.
To configure LAN Destinations:
1. Select the number of slots to be configured. This should be the same number of slot that you have
selected in the Alert Policies Destination Selector field. That is, if you have selected the Destination
Selector as 4, then you have to configure the 4th slot of LAN Destination page.
2. Select the slot for which you want to configure to open the LAN Destination entry.
3. In the LAN Channel Number field, the LAN Channel Number for the selected slot is displayed and this is
a read only field.
4. In the LAN Destination field, the destination for the newly configured entry is displayed and this is a
read only field.
5. In the Destination Type field, select the one of the types.
6. In the SNMP Destination Address field, enter the destination address.
Note: If Destination type is E-mail Alert, then provide the e-mail address that will receive the e-mail.
7. If the destination type is Email alert, select the BMC Username from the list of users.
Note: E-mail address should be configured under Settings User Management.
8. In the Email Subject field, enter the subject.
9. In the Email Message field, enter the message.
10. Click Save to save the new LAN destination and return to LAN destination list.
11. Click
in the LAN Destinations page to send sample alert to configured destination.
Note: Test alert can be sent only with SMTP configuration is enabled. SMTP support can be enabled
under Settings SMTP Settings.
Chapter 4. Basic configurations 21
Services
Display the basic information about services running in the BMC. Only Administrator can modify the service.
Settings name Description
Services Display service name of the selected slot (read-only).
Status Display the current status of the service, either active or inactive state.
Interfaces Show the interface in which service is running.
Secure Port Used to configure secure port number for the service.
Web default port is 443
KVM default port is 443
CD Media default port is 443
HD Media default port is 443
SSH default port is 22
Note: Telnet default port is 23 and does not support secure port. If
single port feature is enabled, KVM, CD Media and HD Media ports
cannot be edited. Port value ranges from 1 to 65535.
Timeout Display the session timeout value of the service. For web, SSH and
telnet service, user can configure the session timeout value.
Notes:
Web timeout value ranges from 300 to 1800 seconds.
KVM timeout value ranges from 300 to 1800 seconds.
SSH and Telnet timeout value ranges from 60 to 1800 seconds.
SSH and telnet service will be using the same timeout value. If you
configure SSH timeout value, it will be applied to telnet service also
and vice versa.
If KVM is launched, then the web session timeout will not take
effect.
Maximum Sessions Display the maximum number of allowed sessions for the service.
Active Sessions View the current active sessions for the service.
To view the active sessions, click to view the details about the active sessions for the service in the Active
Session page. Select a slot and click
to terminate the particular session of the service.
Settings name Description
Session ID Display the ID of the active sessions.
Session Type Display the type of the active sessions.
User ID Display the ID of the user.
Username Display the name of the user.
Client IP Displays the IP addresses that are already configured for the active
sessions.
Privilege Display the access privilege of the user.
To modify the existing services:
1. Select a slot and click
to modify the configuration of the service.
22
ThinkStation BMC remote management console User Guide
Note: Whenever the configuration is modified, the service will be restarted automatically. User must
close the existing opened session for the service if needed.
2. The Service Configuration page is displayed. Service Name is a read only field.
3. Activate the current state by checking Active.
Note: Interfaces, Secure port, Timeout and Maximum Sessions will not be active unless the current
state is active.
4. Select any one of the available interfaces from the Interface Name drop-down list box.
5. Enter the Secure Port Number in the Secure Port field.
6. Enter the timeout value in the Timeout field.
Note: The values in the Maximum Sessions field cannot be modified.
7. Click Save to save the changes and click Cancel to exit.
SMTP Settings
Simple Mail Transfer Protocol (SMTP) is an Internet standard for electronic mail (e-mail) transmission across
Internet Protocol (IP) networks. Using ThinkStation BMC GUI, you can configure the SMTP settings of the
device.
To configure SMTP settings:
1. Select the LAN Interface from the drop-down list box.
2. Enter the Sender Email ID in the specified field.
3. Check Primary SMTP Support to enable SMTP support for the BMC.
4. Enter the Machine Name of the SMTP Server in the Primary Server Name field.
Note: Machine Name is a string of maximum 15 alpha-numeric characters. Space and special
characters are not allowed.
5. Enter IP address of the SMTP Server in the Primary Server IP field. It is a mandatory field.
6. Enter the Primary SMTP Port in the specified field.
7. Enter the Primary Secure SMTP Port in the specified field.
8. Check Primary SMTP Authentication if you want to authenticate SMTP Server.
9. Enter your Primary Username and Primary Password in the respective fields.
10. Check Primary SMTP SSLTLS Enable to send data through secure Port.
Note: If this option is selected, STARTTLS option and Normal Port will be hidden.
11. Check Secondary SMTP Support to enable Secondary SMTP support for the BMC.
12. Enter the Secondary Server Name, Secondary Server IP, Secondary SMTP Port, and Secure Port
values in the respective fields.
13. Check SMTP Server Authentication if you want to authenticate SMTP Server.
14. Enter your Secondary Username and Password in the respective fields.
15. Check Secondary SMTP SSLTLS to send data through secure Port.
Note: If this option is selected, STARTTLS option and Normal Port will be hidden.
16. Click Save to save the entered details.
Chapter 4. Basic configurations 23
SSL Settings
The Secure Socket Layer protocol was created by Netscape to ensure secure transactions between web
servers and browsers. The protocol uses a third party, a Certificate Authority (CA), to identify one end or both
end of the transactions.
Configure SSL certificate into the ThinkStation BMC so that the device can be accessed in a secured mode.
To Configure SSL certificate:
1. Generate SSL Certificate.
Settings name
Description
Common Name (CN) Common name for which certificate is to be generated.
Maximum length of 64 characters.
It is a combined string of alpha-numeric characters.
Special characters ‘#’ and ‘$’ are not allowed.
Organization (O) Organization name for which the certificate is to be generated.
Maximum length of 64 characters.
It is a combined string of alpha-numeric characters.
Special characters ‘#’ and ‘$’ are not allowed.
Organization Unit (OU) Over all organization section unit name for which certificate is to be
generated.
Maximum length of 64 characters.
It is a combined string of alpha-numeric characters.
Special characters ‘#’ and ‘$’ are not allowed.
City or Locality (L) City or Locality of the organization (mandatory).
Maximum length of 128 characters.
It is a combined string of alpha-numeric characters.
Special characters ‘#’ and ‘$’ are not allowed.
State or Province (ST) State or Province of the organization (mandatory).
Maximum length of 64 characters.
It is a combined string of alpha-numeric characters.
Special characters ‘#’ and ‘$’ are not allowed.
Country (C) Country code of the organization (mandatory).
Only two characters are allowed.
Special characters are not allowed.
Email Address
E-mail address of the organization (mandatory)
Valid for Validity of the certificate (Value ranges from 1 to 3650 days).
Key Length The key length bit value of the certificate
Save Click to generate the new SSL certificate.
Note: HTTPs service will get restarted to use the newly generated
SSL certificate.
2. Upload SSL Certificate. This option is used to upload the certificate and private key file into the BMC.
24
ThinkStation BMC remote management console User Guide
Settings name Description
Current Certificate Current certificate and uploaded date or time will be displayed
(read-only).
New Certificate Certificate file should be of pem type.
Current Private Key Current Private key information will be displayed (read-only).
New Private Key Private key file should be of pem type.
Upload To upload the SSL certificate and privacy key into the BMC.
Note: After successful upload, HTTPs service will get restarted to
use the newly uploaded SSL certificate.
Note: If you’d like to use your own security certificate, you can upload your private key and certificate
here. Private key and certificate must be in PEM format.
Security IP/User Block
To enable or disable the Security IP/User Block function.
Add Firewall Settings
Only administrators can add or delete a firewall.
To Add Firewall Settings:
1. Select IPv4, IPv6, or Both from the Block All drop-down list box to block the incoming IPs and ports
you prefer.
Note: Blocking All IPv4 will also block all Redfish requests from the BIOS, which may extend the system
boot time.
2. Check Flush All to flush all the system firewall rules.
3. Check Timeout to enable firewall rules with timeout.
4. Enter Start Time to start the respective firewall rule effect from this time.
5. Enter End Time to end the respective firewall rule effect from this time.
Note: The time should be in the “dd-mm-yy:hh-mm” format.
6. Click Save to save your configuration.
Note: The parameters should be set as you needed. Otherwise, the interface might be blocked
unexpectedly.
Add New IP Rule
The firewall IP rule can be set for an IP or range of IP Addresses
To add an IP rule:
1. Enter an IP address or a range of IP addresses in the IP Single or IP Range Start field.
Notes:
IP Address will support IPv4 Address format only.
IPv4 Address is made of 4 numbers separated by dots as in xxx.xxx.xxx.xxx.
Each number ranges from 0 to 255.
Chapter 4. Basic configurations 25
The first number must not be 0.
IPv6 Address is made of 8 groups of 4 Hexadecimal digits separated by colon as in xxxx:xxxx:xxxx:
xxxx:xxxx:xxxx:xxxx:xxxx.
2. Enter IP range end value in the IP Range End field.
3. Check Timeout to enable firewall rules with timeout.
4. Enter Start Date to start the respective firewall rule effect from this date.
5. Enter End Date to end the respective firewall rule effect from this date.
6. Enter Start Time to start the respective firewall rule effect from this time.
7. Enter End Time to end the respective firewall rule effect from this time.
Note: The time should be in the dd-mm-yy:hh-mm format.
8. Select Block or Allow from the Rule drop-down list box.
9. Click Save to save your configuration.
Note: If there are conflicting rules, the most recently defined rule takes precedence.
Add New Port Rule
The firewall Port rule can be set for a Port number or range of Port numbers.
To Add New Port Rule:
1. Enter the port number or a range of port numbers in the Port Single (or) Range Start field.
Note: Port value ranges from 1 to 65535.
2. Enter the end value in the Port Range End field.
3. Select either TCP, UDP, or Both from the Protocol drop-down list box.
4. Select IPv4 or IPv6 or Both from the Network Type drop-down list box.
5. Check Enable Timeout to enable firewall rules with timeout.
6. Enter Start Date to start the respective firewall rule effect from this time.
7. Enter Start Time to start the respective firewall rule effect from this date.
8. Enter End Date to end the respective firewall rule effect on this date.
9. Enter End Time to end the respective firewall rule effect at this time.
Note: The time should be in the YYYY/MM/DD:hh-mm format.
10. Select Block or Allow from the Rule drop-down list box.
11. Click Save to save your configuration.
Note: If there are conflicting rules, the most recently defined rule takes precedence.
User Management
View the current list of user slots for the server. You can add a new user and modify or delete the existing
users.
To add a new user:
1. Select a free section and click on the blank area to open the Add User screen.
2. Enter the name of the user in the Username field.
Notes:
26
ThinkStation BMC remote management console User Guide
Username is combined a string of 1 to 16 alpha-numeric characters.
It must start with an alphabetical character.
It is case-sensitive.
Special characters like ‘-’(hyphen), ‘_’(underscore), and ‘@’(at sign) are allowed. For 20 Bytes
password, LAN session will not be established.
3. Select a password size from the Password Size drop-down list box for the new password.
4. In the Password and Confirm Password fields, enter and confirm your new password.
Notes:
Password should be the combination of alphabets, numbers, symbol and upper-case characters.
White space is not allowed.
This field will not allow more than 16/20 characters based on Password size field value.
This field will not allow the below mentioned characters.
The password should be a string, if you try to set password using “ipmitool user set password”.
Hex
Char
Hex
Char
00
NUL ‘\0’
11
DC1 (device control 1)
01
SOH (start of heading)
12
DC2 (device control 2)
02
STX (start of text)
13
DC3 (device control 3)
03
ETX (end of text)
14
DC4 (device control 4)
04
EOT (end of transmission)
15
NAK (negative ack.)
05
ENQ (enquiry)
16
SYN (synchronous idle)
06
ACK (acknowledge)
17
ETB (end of trans. blk)
07
BEL ‘\a’ (bell)
18
CAN (cancel)
08
BS ‘\b’ (backspace)
19
EM (end of medium)
09
HT ‘\t’ (horizontal tab)
1A
SUB (substitute)
0A LF ‘\n’ (new line) 1B ESC (escape)
0B
VT ‘\v’ (vertical tab) 1C FS (file separator)
0C FF ‘\f’ (form feed)
1D
GS (group separator)
0D
CR ‘\r’ (carriage ret)
1E
RS (record separator)
0E
SO (shift out)
1F
US (unit separator)
0F SI (shift in)
20
SPACE
10
DLE (data link escape)
7F DEL
5. Enable or Disable the Enable User Access Privilege.
Notes:
Enabling User Access will intern assign the IPMI messaging privilege to user.
It is recommended that the IPMI messaging option should be enabled for the user to enable the User
Access option, while creating User through IPMI.
Chapter 4. Basic configurations 27
6. In the Privilege field, enter the privilege assigned to the user which could be Administrator, Operator,
User, OEM or None. By default, the channel privileges will be displayed based on the channel
availability.
Notes:
The default OEM privilege is set to “Administrator” before customization.
The Callback privilege will only be displayed in the Privilege field if it’s assigned through other
interfaces. It cannot be set directly in the Web UI like other privileges.
7. Check KVM Access to assign the KVM privilege for the user.
8. Check VMedia Access assign the VMedia privilege for the user.
Notes:
It is recommended that the privileges support to KVM and VMedia should be provided only to the
ADMIN user and shouldn’t be provided to USER and OPERATOR privilege level users. The
administrator can provide the privilege support to user and operator privilege level users at their own
risk.
VMedia Privilege only restricts initiating / starting media redirection. If a device is already being
redirected and attached to the host, then in host it will be visible as normal device. Hence it will be
accessible to all the KVM sessions. Which includes ‘KVM Privilege only’ sessions as well.
9. Check SNMP Access to enable SNMP access for the user.
Note: Password field is mandatory if SNMP Status is enabled.
10. Choose the SNMP Access level option for user from the SNMP Access level (SHA or MD5) drop-down
list box. Either it can be Read Only or Read Write.
11. Choose the SNMP Authentication Protocol (SHA or MD5) to use for SNMP settings from the drop-
down list box.
Note: Password field is mandatory if Authentication protocol is changed.
12. Choose the Encryption algorithm to use for SNMP settings from the SNMP Privacy protocol (AES or
DES) drop-down list box.
13. Select an e-mail format from the Email Format drop-down list box:
AMI-Format: The subject of this mail format is ‘Alert from (your Host name)’. The mail content shows
sensor information, ex: Sensor type and Description.
Fixed-Subject Format: This format displays the message according to user’s setting. You must set
the subject and message for e-mail alert.
14. In the Email ID field, enter the e-mail ID of the user. If the user forgets the password, the new password
will be mailed to the configured e-mail address.
Note: SMTP Server must be configured to send e-mails.
15. In the Upload SSH Key field, click Browse and select the SSH key file.
Note: SSH key file should be of pub type.
16. Click Save to save the new user and return to the users list.
To modify a user:
1. Click the active user tab to open a user screen.
2. Check Change Password if you wish to change the existing Password.
3. Follow the steps (3 to 15) of Procedure to add a new User.
28
ThinkStation BMC remote management console User Guide
4. Click Save to save the changes and return to the users list.
5. Click Delete to delete the user.
Important: There are certain reserved users which cannot be added as BMC Users. The list of reserved
users are as below:
sysadmin
daemon
sshd
ntp
root
IPMI Interfaces
Used to configure the IPMI Interfaces. You can enable or disable the IPMI Over LAN function in this page.
And if 'IPMI Over LAN' is disabled, it means IPMI communication will not work over LAN interface.
Power Control
Allow you to view and control the power of your computer. Select an action and click Perform Action to
proceed with the selected action. During Execution you will be asked to confirm your choice. Upon
confirmation, you will be informed about the status after a few minutes.
Settings name
Description
Power Off Immediately power off the computer.
Power On
Power on the computer.
Power Cycle First power off, and then reboot the system (cold boot).
Hard Reset
Reboot the system without powering off (warm boot).
ACPI Shutdown Initiate operating system shutdown prior to the shutdown.
Perform Action Click to perform the selected operation.
Chapter 4. Basic configurations 29
30 ThinkStation BMC remote management console User Guide
Chapter 5. Advanced configurations
Network Settings
The Network Settings page is used to configure the network settings for the available LAN channels.
Network IP Settings
To configure Network IP:
1. Check Enable LAN to enable LAN support for the selected interface.
2. Select a LAN interface to be configured in the LAN Interface field.
3. Check Enable IPv4 to enable IPv4 support for the selected interface.
4. Check Enable IPv4 DHCP to dynamically configure IPv4 address using DHCP.
5. If the field is disabled, enter the IPv4 Address, IPv4 Subnet and IPv4 Gateway in respective fields.
Notes:
IP address is made of 4 numbers separated by dots as in “xxx.xxx.xxx.xxx”.
Each number ranges from 0 to 255.
The first number must not be 0.
6. In IPv6 configuration, if you wish to enable the IPv6 settings, check Enable IPv6.
7. If the IPv6 setting is enabled, enable or disable the option Enable IPv6 DHCP.
8. If the field is disabled, enter the IPv6 Address, Subnet Prefix length (Value ranges from 0 to 128), IPv6
Gateway and IPv6 Index in respective fields.
Note: If core feature IPV6_COMPLIANCE is enabled, the IPV6 default Gateway field will not be
displayed.
9. In VLAN configuration, if you wish to enable the VLAN settings, check Enable LAN.
10. Enter the VLAN ID in the specified field (Value ranges from 2 to 4094).
11. Enter the VLAN Priority in the specified field (Value ranges from 0 to 7).
12. Click Save to save the entries.
Network Bond Configuration
This setting is used to configure the network bonding for the network interface. At least two network
interfaces are required to enable Network bonding for the device.
The Enable Bonding option is enabled. You can disable the option if needed.
To configure Network bonding:
1. Select the bond interface from the Bond Interface drop-down list box.
Note: The bond interface can be selected only if the Enable Bonding option is enabled.
2. Check Auto Configuration to enable the auto configuration.
Notes:
The Link Speed and Duplex Mode will be active only when Auto Configuration is disabled.
© Copyright Lenovo 2024 31
Use Auto Configuration by default. Use other modes based on network settings.
3. Select the link speed from the Link Speed drop-down list box.
Note: Link speed of 1000 Mbps is not applicable when Auto Configuration is disabled.
4. Select either Full duplex or Half duplex from the Duplex Mode drop-down list box
5. Click Save to save the configuration.
Network Link Configuration
This setting is used to configure the network link configuration for available network interfaces.
To configure network link:
1. Select the LAN interface from the LAN Interface drop-down list box.
2. Check or clear Auto Negotiation.
Notes:
The Link Speed and Duplex Mode will be active only when Auto Negotiation is disabled.
Use Auto Negotiation by default. Use other modes based on network settings.
3. Select the link speed from the Link Speed drop-down list box.
Note: Link speed of 1000 Mbps is not applicable when Auto Negotiation is disabled.
4. Select either Full duplex or Half duplex from the Duplex Mode drop-down list box.
5. Click Save to save the configuration.
DNS Configuration
The Domain Name System (DNS) is a distributed hierarchical naming system for computers, services, or any
resource connected to the Internet or a private network. It associates the information with domain names
assigned to each of the participants. Most importantly, it translates domain names meaningful to humans
into the numerical (binary) identifiers associated with networking equipment for the purpose of locating and
addressing these devices worldwide.
The DNS configurations are used to manage the DNS settings of a device.
To configure DNS:
1. Check DNS Enabled to enable all DNS services.
2. Select either Automatic or Manual for the Host Name Setting option.
Note: If you select Automatic, you need not to enter the host name and if you select Manual, you need
to enter the host name.
3. Enter the host name in the Host Name field if you have selected Manual.
4. In the BMC Registration Settings section, choose the BMC’s network interface to register with DNS
settings.
a. Check Register BMC to register with DNS settings.
b. Select the Registration method.
Select Nsupdate to register with DNS server using nsupdate application.
Select DHCP Client FQDN to register with DNS Server using DHCP option 81.
Select Hostname to register with DNS server using DHCP option 12.
32
ThinkStation BMC remote management console User Guide
Note: Hostname option should be selected if the DHCP Client FQDN option is not supported by
DHCP server.
5. Check Both to modify TSIG authentication for both interfaces (eth0&1).
6. In Eth 0&1 TSIG Configuration, Check TSIG Authentication Enabled to enable or disable TSIG
authentication while registering DNS via nsupdate.
The current file name will be displayed in Current TSIG Private file info field.
To view a new one, click New TSIG private file to browse and navigate to the TSIG private file.
7. In the Domain Settings section,
Select the domain settings (Automatic or Manual).
Enter the Domain Name in the given field if the option Manual is selected in domain settings field.
8. In Domain Name Server Setting,
Select the DNS Name Server Setting.
Select the IP Priority, either IPv4 or IPv6.
Enter the DNS server address.
9. In DNS Server1, DNS Server2, and DNS Server3 fields, enter the server addresses to be configured for
the BMC.
10. Click Save to save the entries.
Sideband Interface (NC-SI)
To configure NC-SI settings:
1. Select either Auto Failover Mode or Manual Switch Mode for NCSI Mode type.
Notes:
If you select Auto Failover Mode, the NCSI Interface will be configured automatically.
If you select Manual Switch Mode you are only allowed to configure NCSI interface, channel
number, and package ID.
2. Select a particular interface name for which to configure NCSI settings from the NCSI Interface drop-
down list box.
3. Select the package ID to be configured for the selected interface name from the Package ID drop-down
list box.
4. Select the channel number to be configured for the selected interface name from the Channel Number
drop-down list box.
5. Click Save to save the current changes.
Video Recording
The Network Settings page is used to configure the Video Recording. The first 3 options are used to
configure the events that will trigger auto video recording function of the KVM server. And the last 3 options
are used to configure and record the SOL log events.
Auto Video Trigger Settings
To configure auto video trigger:
1. Select the events to be enabled from the event list.
Notes:
Chapter 5. Advanced configurations 33
KVM service should be enabled to perform auto-video recording.
The Date field and Time field should be set in advance to the system date and time if Date and Time
Event is checked.
Disable or enable pre-event recording selection for newly modified configuration in Auto Pre-Event
Video Recordings to take effect.
Pre-Event video recording will not occur when active KVM session or Post-Event video recording is in
progress.
2. Click Save to save the changes.
Auto Video Remote Storage
To enable or disable Remote Video support, check or uncheck theRecord Video to Remote Server
checkbox. By default, video files will be stored in the local path of the BMC. If the remote video support is
enabled, then the video files will be stored only in the remote path, and not within the BMC.
To record video to remote server:
1. Check Record Video to Remote Server to enable the remote video support.
Note: By default, video files will be stored in local path of BMC. If remote video support is enabled, then
the video files will be stored only in remote path, not within BMC.
2. Enter Maximum Dumps, Maximum Duration (Second), and Maximum Size (MB) of the video in
respective fields.
Note: The maximum dumps should be in the range from 1 to 100. The maximum duration of the video
should be in the range from 1 to 3600 seconds. The maximum size of the video should be in the range
from 1 to 500 MB. The recorded video file should meet either the size constraint or duration constraint,
according to the configured settings, depending on which constraint is met first.
3. Enter the Server Address.
Notes: The server address will support the following:
IP Address (Both IPv4 and IPv6 format).
FQDN (Fully qualified domain name) format.
4. Enter the source path in Path in Server field.
5. Select the Share Type (NFS or CIFS). If you select CIFS, enter the Username, Password and Domain
Name in respective fields.
6. Click Save to save the settings.
Auto Pre-Event Video Recordings
Used to configure the Pre-Event video recording options. Pre-Event video recording is disabled by default.
To enable the Pre-Event video recording, go to the Auto Video Trigger Settings page.
To configure Pre-Event video recording:
1. Select quality (very low, low, average, normal, or high) from the Video Quality drop-down list box.
2. Select modes (high, normal, low, or no) from the Compression Mode drop-down list box.
3. Select frames per second (1-4) from the Frames Per Second drop-down list box.
4. Select second (10-60) from the Video Duration drop-down list box.
5. Click Save to save the changes made on the Pre-Event Video Recording.
34
ThinkStation BMC remote management console User Guide
Pre-Event
Pre-Event video recording files will be named as per event captured. For example, if any video is recorded for
crash event, the recorded file will be named as pre_crash_video_x.dat, where x is file count, similarly if it is
recorded for reset event it will be named as pre_reset_video_x.dat.
Post-Event
Post-Event video recording files will be named as video_dump_<Hostname>_%y%m%d%H%M%S.dat.
File count and duration for Pre and Post Event Recordings are as shown in the below table.
Items
Auto Video Recording (Post Event) Post Event) Pre-Event Video
Recording (only for crash or reset
event)
Time Limits
20 seconds or 5.5MB video
allowed if local storage.
3600 seconds or 500MB video
recording allowed if remote
storage (remote path).
Default value is 10 seconds but can
be configured up to 60 seconds.
Video File Count
local storage: 2 (After 2, if video
recording starts, the older video
file among the two files will be
replaced with the new video)
remote storage: maximum
configured dump value of video
files for remote storage.
1 if local storage or 3 if remote
storage. (Once the maximum file
count is reached, will delete the old
video file to store the new file.)
SOL Trigger Settings
Used to configure which event on the page will trigger the SOL log.
To configure SOL Trigger:
1. Check the events to be enabled to configure which event will trigger the SOL log option to start.
Note: The Date and Time field should be set in advance to the system date and time if Date and Time
Event is checked.
2. Click Save to save the changes.
SOL Log Settings
To configure recorded video files:
1. Enter the log size in the Log Size (KB) field. The value supports a maximum length of 10 digits.
2. Enter the log file count in the Log File Count field. The Maximum number of log files count is 1.
3. Check Record Video to Remote Server to enable the remote video support.
Note: The Server Address, Source Path, and Share Type options will be enabled only if the Remote
Video Support option is enabled.
4. Enter the server address in the Server Address filed and the source path in the Path in server filed.
Notes: Server address will support the following:
IP Address (Both IPv4 and IPv6 format)
Chapter 5. Advanced configurations 35
FQDN (Fully qualified domain name) format
5. Select NFS or CIFS for the Share Type option. If you select CIFS, Enter the username, password and
domain name in respective fields.
6. Click Save to save the settings.
Notes:
If the proper SOC specific video driver is installed in the host, only video changes will be captured during
the video recording process.
The host cursor data, in this case, will not be a part of the video changes, and hence the host cursor will
not be available in the recorded video file (DAT file).
SOL Configurations
Used to configure the Baud rate between the BMC card and the host. You can select the Volatile Bit Rate
and the Non-Volatile Bit Rate from the drop-down list box according to your device configuration.
Remote Control
KVM Mouse Settings
The Redirection Console handles mouse emulation from the local window to the remote screen using any of
three methods. Only an Administrator user has the rights to configure this option.
To configure the Mouse mode:
1. Select either of the following as your requirement:
Relative Positioning (Linux)
Note: Applicable for all Linux versions, versions less than RHEL6, and versions less than FC14.
Absolute Positioning (Windows)
Note: Applicable for all Windows versions, versions above RHEL6, and versions above FC14.
Other Mode
Note: Recommended for SLES-11 OS Installation.
2. Click Save to save the changes made.
Note: If the client and host mouse position is not in sync, then check the release notes of the host
operating system to verify any additional configuration to be needed in the Host.
Remote Session
Used to configure remote session settings.
To configure remote session:
1. Select JViewer/H5Viewer or VNC for the KVM Client Type option.
2. Select the keyboard language from the Keyboard Language drop-down list box.
3. Select the virtual media attach mode from the Virtual Media Attach Mode drop-down list box.
4. Enter a value in the Retry Count field to set the number of attempts for retrying the redirection session.
5. Enter a value in the Retry Time Interval (Seconds) field to give time interval for each attempt.
36
ThinkStation BMC remote management console User Guide
6. Check Server Monitor OFF Feature Status to enable the local monitor on/off command during runtime.
7. Check Automatically OFF Server Monitor, When KVM Launches to automatically lock the local
monitor during H5Viewer launch.
8. Click Save to save the current changes.
Remote Control
Used to define the system and browser requirements for Remote Control are given below.
Launch H5Viewer
System Requirements:
Client machine with 8GB RAM.
If the client machine has 4GB RAM, there will be lag in video, keyboard, and mouse functionality.
Supported Browsers:
Chrome latest version.
IE11 and above.
Firefox (with limited support).
Note: It is advisable to use Chrome or IE for H5Viewer, since Firefox has its own memory limitations.
To start or stop KVM:
1. Click Launch H5Viewer to open the Remote KVM page.
2. To stop the H5Viewer video redirection, click Stop KVM.
To Start or stop Media:
1. Click Browse File to select CD Image.
2. Click Start Media to redirect the selected CD image file to the Host.
Note: To use KVM CD/DVD media redirection, make sure that the Remote KVM CD/DVD device
instances are not set to 0. For specific settings, refer to “VMedia Instance Settings” on page 50.
3. To stop the CD Image redirection, click Stop Media. A detailed description of the menu items is as
below:
Chapter 5. Advanced configurations 37
Settings name Description
Video
Pause Video: This option is used for pausing Console Redirection.
Resume Video: This option is used to resume the Console
Redirection when the session is paused.
Refresh Video: This option can be used to update the display
shown in the Console Redirection window.
Host Display: The display of the host.
Display on: If you enable this option, the display will be shown on
the screen in the server screen. If you disable this option, the
display will be shown on the screen in Console Redirection only.
Display off: If you enable this option, the server display will be
blank, but you can view the screen in Console Redirection. If you
disable this option, the display will be back in the server screen.
Capture Screen: This option helps to take the screenshot of the
host screen and save it in the client’s system.
Mouse
Show Client Cursor: This menu item can be used to show or hide
the local mouse cursor on the remote client system.
Mouse Mode: This option handles mouse emulation from local
window to remote screen using either of the two methods. Only an
Administrator user has the right to configure this option.
Absolute mouse mode: The absolute position of the local
mouse is sent to the server if this option is selected.
Relative mouse mode: The Relative mode sends the calculated
relative mouse position displacement to the server if this option
is selected.
Other mouse mode: This mouse mode sets the client cursor in
the middle of the client system and will send the deviation to the
host. This mouse mode is specific for SUSE Linux installation.
Note: Client cursor will be hidden always. If you want to enable, use
Alt+C to access the menu.
Options
Zoom
Normal: By default this option is selected.
Zoom In: For increasing the screen size. This zoom varies from
100% to 150% with an interval of 10%.
Zoom Out: For decreasing the screen size. This zoom varies
from 100% to 50% with an interval of 10%.
Bandwidth: This option helps to choose the bandwidth between
BMC and the host.
Block Privilege Request: To enable or disable the access privilege
of the user.
*Compression Mode: This option helps to compress the Video
data transfer to the specific mode.
*DTC Quantization Table: This option helps to choose the video
quality from 0 to 7, and 0 means best quality.
Note: *Specific to AST SOC.
38 ThinkStation BMC remote management console User Guide
Settings name Description
Keyboard
Keyboard Layout: This feature is fully compatible when host and
client has the same keyboard language layout. If the client and host
language layouts differ, some special characters will not be
compatible.
List of Host Physical Keyboard languages supported in SPX
H5Viewer.
English U.S.
German.
Japanese.
Send Keys: This option is used to key items. This menu contains
the following sub menu items.
Hold Down
Right Ctrl Key: This menu item can be used to act as the
right-side <CTRL> key when in Console Redirection.
Right Alt Key: This menu item can be used to act as the
right-side <ALT> key when in Console Redirection.
Right Windows Key: This menu item can be used to act as
the right-side <WIN> key when in Console Redirection.
Left Ctrl Key: This menu item can be used to act as the left-
side <CTRL> key when in Console Redirection.
Left Alt Key: This menu item can be used to act as the left-
side <ALT> key when in Console Redirection.
Left Windows Key: This menu item can be used to act as the
left-side <WIN> key when in Console Redirection. You can
also decide how the key should be pressed: Hold Down or
Press and Release.
Press and Release
Ctrl+Alt+Del: This menu item can be used to act as if you
depressed the <CTRL>, <ALT>, and <DEL> keys down
simultaneously on the server that you are redirecting.
Left Windows Key: This menu item can be used to act as the
left-side <WIN> key when in Console Redirection. You can
also decide how the key should be pressed: Hold Down or
Press and Release.
Right Windows Key: This menu item can be used to act as
the right-side <WIN> key when in Console Redirection.
Context Menu Key: This menu item can be used to act as
the context menu key, when in Console Redirection.
Print Screen Key: This menu item can be used to act as the
print screen key, when in Console Redirection.
Hot Keys This menu is used to add the user configurable shortcut keys to
invoke in the host machine. The configured key events are saved in
the BMC.
Add Hot Keys: This menu is used to enable macros. Click Add to
macros.
Chapter 5. Advanced configurations 39
Settings name Description
Video Record Record Video: This option is to start recording the screen.
Stop Recording: This option is used to stop the recording.
Record Settings: This option is used to set video record duration and
video compression value. Video record duration value should be in
the range of 1 to 1800 seconds. Video Compression value should be
in the range of 0.1 (Low image quality) to 0.9. (High image quality).
Normalized video resolution to 1024 x 768: Host video will be
scaled to 1024 x 768 in the recorded video file. Enabling this option
improves video recording performance of client side in H5Viewer.
Disable this option to record video at same resolution as host video.
The host video capture depends on client system performance. If this
option is disabled, recorded video file may have inconsistency. (i.e.,
Recorded video file duration may not be the same as configured
value).
Notes:
The Maximum video file size allowed is around 40MB. If the video
file size reaches its max size limit, the recorded file will be
downloaded, and the recording will be in progress until the
configured video recording time is reached. The video file is saved
as video_date-month-year_hr-min-sec_partno in client-side video
recording.
User must take care of saving the video files in different browsers.
When H5viewer focus is lost and if video recording is in progress,
the recording will be stopped with a notification message and the
recorded video file will be discarded.
Due to browser limitation, set timeout/set interval will be delayed
from specified time of interval when browser window loses focus,
hence video server will not send the video packets to H5viewer and
so the video recording will be stopped.
Power
The power options are to perform any power cycle operation. Click on
the required option to perform the following operation.
Reset Server: To reboot the system without powering off (warm
boot).
Immediate Shutdown: To perform Power OFF Immediately.
Orderly Shutdown: To Power OFF the sever in proper order.
Power ON Server: To Power ON the server.
Power Cycle Server: To first power off, and then reboot the
system (cold boot).
Active Users
Click this option to display the active users and their system IP
address.
Active KVM Session can be terminated when there are multiple KVM
session from master [FULL Privilege KVM Session].
Help
Click this option to get more information About H5Viewer. The KVM
Remote Console utility version and plugin version will be displayed.
The upper right of H5Viewer window displays all the quick buttons which allow you to perform the below
functions.
40
ThinkStation BMC remote management console User Guide
Quick Buttons Description
This quick button shows or hides notifications dropdown menu, which
contain the list of notifications displayed by H5Viewer.
This quick button shows the current zoom value in percentage.
This quick button is used to display the current host monitor status. If
icon is in green, then host monitor is unlocked. If the icon is in red,
host monitor is locked. By clicking the button host monitor status can
be toggled.
This quick button is used to display the current server power status. If
the icon is in green color, the server status is powered on. If the icon is
in red color, the server status is powered off. Click the button to
toggle immediate power off / power on the host.
Status bar buttons:
Keyboard LED Sync
When the H5Viewer is launched, the keyboard locks status and LEDs denoting the lock status of the host
machine, should be in sync with the client machine. That is, if the Num/Caps/Scroll lock is enabled or
disabled in the client machine, the same should be updated in the host machine as well.
Notes:
Due to web browser related security concerns this feature has following limitations.
Host LED status will be synced with client LED status, only if user presses any key in client keyboard when
H5Viewer window is in focus.
Client keyboard LED status cannot be updated.
This functionality is not available in safari web browser.
Control keys
This option provides the same functionality of Send Keys Hold Down menu item. Select any of the menu
item, it will highlight the corresponding status bar button in green color. Similarly, by clicking the buttons will
toggle the selection status of the corresponding menu item.
H5Viewer browser limitations
This section describes the H5Viewer limitations of different browsers.
All browsers:
To use secure H5Viewer sessions, adding an SSL certificate to the browser is mandatory.
H5Viewer video record length (client-side video recording length set by a user) will differ from the
downloaded video file duration. The recorded video duration depends on the browser, and the amount
of host video update.
Keyboard LED sync will not work when the host is the Linux text console.
Clearing H5Viewer sessions will take some time when a user abruptly closes the H5Viewer window.
Chapter 5. Advanced configurations 41
If any dialog (like File Choose, Confirmation dialog, etc) in H5Viewer is kept open and not closed, then
the background functionalities of threads might get affected leading to H5Viewer reconnect or
connection close.
Google Chrome: Upon launching, the H5Viewer window will not be resized to the client resolution.
Firefox: Only the Japanese QWERTY input method will work. The Japanese hiragana or katakana input
method will not work.
Safari:
Keyboard LED sync will not work.
To use secure H5Viewer sessions, adding an SSL certificate to the browser is mandatory.
Launch JViewer
This is an OS-independent plug-in which can be used in Windows as well as Linux with the help of Java
Runtime Environment (JRE). JRE should be installed in the client’s system.
Note: It is recommended to use openJDK 8 or any later LTS version. IcedTea-Web launch applications may
work inconsistently when JDK 11 or a later version is used. The Web launch dialog may freeze and become
unresponsive.
Procedure to launch JViewer:
1. Download the .jnlp file from the BMC.
2. Open the .jnlp file using the appropriate JRE version (Javaws).
When the downloading is done, it opens the console redirection window.
A detailed explanation of the menu items are given below:
42
ThinkStation BMC remote management console User Guide
Settings name Description
Video
Pause redirection: This option is used for pausing console
redirection.
Resume Redirection: This option is used to resume the console
redirection when the session is paused.
Refresh Video: This option can be used to update the display
shown in the console redirection window.
Capture Screen: This option helps to take the screenshot of the
host screen and save it in the client’s system.
Compression mode: This option helps to compress the video data
transfer to the specific mode.
DTC Quantization Table: This option helps to choose the video
quality.
Turn OFF Host Display/Host Video Output: If you enable this
option, the server display will be blank but you can view the screen
in console redirection. If you disable this option, the display will be
back in the server screen.
Low Bandwidth Mode: This option is used to control the video
packet dataflow in the network.
Full Screen: This option is used to view the console redirection in
full screen mode (Maximize). This menu is enabled only when both
the client and host resolution are same.
Exit: This option is used to exit the console redirection screen.
Keyboard
Hold Right Ctrl Key: This menu item can be used to act as the
right-side <CTRL> key in console redirection.
Hold Right Alt Key: This menu item can be used to act as the right-
side <ALT> key in console redirection.
Hold Left Ctrl Key: This menu item can be used to act as the left-
side <CTRL> key in console redirection.
Hold Left Alt Key: This menu item can be used to act as the left-
side <ALT> key in console redirection.
Left Windows Key: This menu item can be used to act as the left-
side <WIN> key in console redirection. You can also decide how
the key should be pressed: Hold Down or Press and Release.
Right Windows Key: This menu item can be used to act as the
right-side <WIN> key in console redirection. You can also decide
how the key should be pressed: Hold Down or Press and Release.
Ctrl+Alt+Del: This menu item can be used to act as if you
depressed the <CTRL>, <ALT>, and <DEL>keys down
simultaneously on the server that you are redirecting.
Context menu: This menu item can be used to act as the context
menu key in console redirection.
Hot Keys: This menu is used to add the user configurable shortcut
keys to invoke in the host machine. The configured key events are
saved in the BMC.
Full Keyboard Support: Enable this option to provide full keyboard
support. This option is used to trigger the Ctrl and Alt keys directly
to host from the physical keyboard.
Chapter 5. Advanced configurations 43
Settings name Description
Mouse
Show Cursor: This menu item can be used to show or hide the
local mouse cursor on the remote client system.
Mouse Calibration: This menu item can be used only if the mouse
mode is relative. In this step, the mouse threshold settings on the
remote server will be discovered. The local mouse cursor is
displayed in red color and the remote cursor is part of the remote
video screen. Both the cursors will be synchronized in the
beginning. Use the ‘+’ or ‘-’ key to change the threshold settings
until both the cursors go out of sync. Detect the first reading on
which cursors go out of sync. Once this is detected, use ‘ALT-T’ to
save the threshold value.
Show Host Cursor: This option is used to enable or disable the
visibility of the host cursor. Specific video drivers should be
installed in the host for this feature to work.
Note: Remote KVM supports mouse move, and left and right
button clicks only.
Mouse Mode: This option handles mouse emulation from local
window to remote screen using any of the following methods. Only
administrators have the right to configure this option.
Absolute mouse mode: The absolute position of the local
mouse is sent to the server if this option is selected.
Relative mouse mode: The relative mode sends the calculated
relative mouse position displacement to the server if this option
is selected.
Other mouse mode: This mouse mode sets the client cursor in
the middle of the client system and will send the deviation to the
host. This mouse mode is specific for SUSE Linux installation
and accessing mouse in the UEFI screen.
Notes:
Users are advised to use Linux version of OS except SUSE 11.4
with BMC to avoid mouse sync issues in absolute mouse mode.
The client cursor will be hidden always. If you want to enable it,
use Alt+C to access the menu.
You can see client and host cursors in JViewer if the mouse is
moved faster or in circle. Mouse sync will depend on many
factors like network, client machine video packet receiving and
rendering, and BMC CPU utilization. In normal use cases, you
will have better mouse sync, compared to heavy video or stress
testing scenarios. High resolution and media redirection (copy)
will have direct impacts on video rendering because the client or
host cursor can be viewed while moving the cursor.
Options
Bandwidth: The bandwidth usage option allows you to adjust the
bandwidth. You can select one of the following:
Auto Detect: This option is used to detect the network
bandwidth usage of the BMC automatically.
256 Kbps
512 Kbps
1 Mbps
10 Mbps
44 ThinkStation BMC remote management console User Guide
Settings name Description
Keyboard/Mouse Encryption: This option allows you to encrypt
keyboard inputs and mouse movements sent between the
connections.
Zoom:
Zoom In: This option is used for increasing the screen size. This
zoom varies from 100% to 150% with an interval of 10%.
Zoom Out: This option is used for decreasing the screen size.
This zoom varies from 100% to 50% with an interval of 10%.
Note: This option is available only when you launch the Java
console.
Actual Size: By default, this option is selected.
Fit to Client Resolution: If the host screen resolution is greater
than the client screen resolution, choose this option to fit the host
screen to the client screen. The host video will be scaled down and
rendered in the KVM console. In this case, the host mouse cursor
will appear smaller than the client mouse cursor. Therefore, the
client and host mouse cursors might not be in perfect sync.
Fit to Host Resolution: If the host screen resolution is smaller than
the client screen resolution, choose this option to resize the
JViewer frame to the host resolution.
Note: This option can be configured from PRJ in MDS.
Send IPMI Command: This option opens the IPMI Command
Dialog. Enter the raw IPMI command in the Hexadecimal field as a
hexadecimal value and click Send. The response will then be
displayed.
GUI Languages: Choose the desired GUI language.
Request Full Permission: Partially permitted sessions can use this
option to request the full permission from the existing fully
permitted session.
Note: This menu option is available only for partially privileged
sessions and full permission sessions will not have this option in
the menu.
Block Privilege Request: Fully privileged sessions can use this
option to block incoming requests from partially privileged
sessions by setting an auto response as either Allow only Video or
Deny Access.
Notes: This menu option is available only for full permission
sessions and partially privileged sessions will not have this option
in the menu. Either of the options can only be selected. Both
options cannot be selected together. To disable Block Privilege
Request, none of the options should be selected in the menu.
If Allow only Video is selected, the slave session will be notified
as KVM Master Session blocked incoming request and it will
always receive Video Only (partial permission).
If Deny Access is selected, the slave session will be notified as
KVM Master Session blocked incoming request and the incoming
KVM session will be closed.
Chapter 5. Advanced configurations 45
Settings name Description
Media
The virtual media application will allow you to redirect different
media to the host system. The application supports CD/DVD, hard
disk/USB devices, as well as image files.
Notes:
If there are two device panels for each device, when you click
Connect, the redirected device panel will be disabled.
Unmounting a device will make the driver disconnect the device
when using Auto Attach. Hence, when unmounting one USB
key, the other USB key will be disconnected and then
reconnected.
The virtual media application can be launched as a standalone
application from the StandAlone connection dialog. It can also be
launched from the JViewer, using the Virtual Media menu. When
launched from JViewer, this application will work like a child dialog
of the JViewer.
Each of the supported devices is listed in a separate tab. Each tab
in the application is described below.
CD/DVD: This tab can be used to start or stop the redirection of
a physical DVD/CD-ROM drive and DVD/CD image file of ISO/
NRG file format.
Hard Disk/USB: This tab can be used to start or stop the
redirection of a hard disk/USB key image and USB key image
such as img/ima.
Notes:
For redirecting hard disk drives, you should have the
administrator privilege (root user in the case of Linux clients).
For Windows 7 and above, the Web browser from which the
KVM redirection will be initiated, should be launched using
the Run as Administrator option. If there are multiple
instances of the Web browser open simultaneously, ensure
that all the instances are launched using the Run as
Administrator option.
For a Windows client, if the logical drive of the physical drive
is dismounted, the logical device is redirected with read/write
permission. Else it is redirected with read permission only.
The USB/hard disk drive can be redirected as a whole
physical drive or individual logical drives.
For a MAC client, external USB hard disk redirection is only
supported. The external hard disk drives should be
unmounted from the client before being redirected.
For a Linux client, fixed hard drive is redirected only as read
mode. It does not support write mode. The USB/hard disk
drive will be redirected as a whole physical drive.
For hard disk image redirection, only the file extension is
validated. The hard disk/USB key device or image will be
redirected to the host as it is. The BMC will not validate the
hard disk medium, and the host OS will take care of this. This
is applicable for all the media redirection client applications.
If the feature Redirect Devices Always in READ and WRITE
Mode is enabled, the internal hard disk drives in the client
46 ThinkStation BMC remote management console User Guide
Settings name Description
machine will not be listed. This information will be displayed
in the status bar of the virtual media application.
If files with hidden attribute are visible in the file open dialog,
the file can be opened and redirected.
If the file is not visible in the file open dialog, the user shall
mention the path of the image file in the file name field of the
file open dialog and then open the image.
TSM stack media redirection supports only basic hard disk
redirection.
Connection Status: This tab provides a collective view of the
redirection status of various virtual media devices.
Note: VMedia privilege only restricts initiating or starting media
redirection. If a device is already being redirected and attached
to the host, then it will be visible as a normal device in the host.
Hence, it will be accessible to all the KVM sessions, including
sessions for KVM privilege only as well.
Keyboard Layout
Auto Detect: This option is used to detect keyboard layout
automatically. If the client and host keyboard layouts are the same,
then for all the supported physical keyboard layouts, you must
select this option to avoid typo errors. If the host and client
languages differ, you can choose the host language layout in the
menu and thereby can directly use the physical keyboard.
Physical Keyboard: This feature is fully compatible when the host
and client have the same keyboard language layout. If the client
and host language layouts differ, some special characters will not
be compatible.
Host Platform: This feature contains two options: Windows and
Linux. When working with a Windows host, the Windows option
should be selected. Similarly, when working with a Linux host, the
Linux option should be selected. This option should be selected
properly for the physical keyboard layout cross mapping to work
properly. By default, Windows will be selected.
Soft Keyboard: This option allows you to select the keyboard
layout. It will show the dialog as similar to the Windows on-screen
keyboard. If the client and host languages are different, you can
select the soft keyboard that corresponds to the host keyboard
layout from the list shown in JViewer, and use it to avoid typo
errors.
Notes:
Different Linux systems follow different keyboard layouts.
Therefore, the soft keyboard displayed uses the standard
windows keyboard layout irrespective of the host OS.
Soft keyboard is applicable only for the JViewer application, not
for other applications in the client system.
Video Record
Start Record: This option is to start recording the screen.
Stop Record: This option is used to stop the recording.
Settings: This option is used to set the settings for video
recording.
Notes: Before you start recording, you have to enter the settings.
Chapter 5. Advanced configurations 47
Settings name Description
1. Click Video Record Settings. The settings page is displayed.
2. Enter the Video Length in seconds.
3. Browse and enter the location where you want the video to be
saved.
4. Enable the option of Normalized video resolution to 1024 X
768.
5. Click OK to save the entries and return to the console redirection
screen.
6. Click Cancel if you don’t wish to save the entries.
7. In the console redirection window, click Video Record Start
Record.
8. Record the process.
9. To stop the recording, click Video Record Stop Record.
Power
Reset Server: To reboot the system without powering off (warm
boot).
Immediate shutdown: To perform power-off immediately.
Orderly shutdown: To power off the server in a proper order.
Power On Server: To power on the server.
Power Cycle Server: To first power off, and then reboot the
system (cold boot).
Active Users Click this option to display the active users and their system IP
addresses.
Help JViewer: displays the copyright and version information.
The lower right of console redirection windows displays all the quick buttons. These quick buttons allow you
to perform the below functions by clicking them.
Note: This option is available only when you launch the Java console.
Button Description
This quick button is used to play the console redirection after being
paused.
This quick button can be used for pausing console redirection.
This quick button is used to view the console redirection in full screen
mode.
Note: Set your client system resolution same as the host system
resolution so that you can view the server in full screen.
This quick button is used to show or hide the soft keyboard.
Drag this quick button to zoom in or out.
This quick button is used to record the video.
48 ThinkStation BMC remote management console User Guide
Button Description
These quick buttons will pop up a virtual media where you can
configure the media.
This quick button is used to show or hide the mouse cursor on the
remote client system.
This quick button is used to switch to Active Users.
This quick button will work like a toggle button.
If the icon is in green, the server status is powered on. Clicking the
button will trigger an immediate shutdown action in the host.
If the icon is in red, the server status is powered off. Click the
button to power on the host.
This quick button displays the available hot keys.
Keyboard LED sync
When the JViewer is launched, the keyboard lock status and LEDs denoting the lock status of the host
machine, should be in sync with those in the client machine. That is, if the Num, Caps, or Scroll lock is
enabled or disabled in the client machine, the same should be updated in the host machine as well. The host
keyboard LED status will be synchronized with the client keyboard, the lock indicators in the JViewer status
bar, and the JViewer soft keyboard. The client keyboard’s LED status before launching JViewer, or before the
JViewer gains focus, will be set back to the client when the focus is lost from the JViewer, or when the
JViewer is closed.
Notes:
For Macintosh® OS X clients, the client keyboard LED sync will not work as the OS does not allow user
applications to alter the keyboard LED status. However, the keyboard lock indicators on the JViewer
status bar, and the JViewer soft keyboard lock status will sync with the host keyboard LED status.
In the case of latest Linux distributions used as the host, the keyboard LED sync will not work if the lock
status is changed using the host physical keyboard directly. However, the sync will work if the LED status
is changed using the on-screen keyboard available in the host OS.
Opening a child dialog in JViewer will cause the focus shift out of JViewer. The client keyboard’s LED
status before launching JViewer, or the JViewer gains focus, will be set back to the client in this case.
Serial Over LAN
One of the powerful tools in IPMI is SOL, which provides serial line access over the management LAN. The
BMC does this by redirecting information destined for the serial port over to the LAN. With SOL console
redirection, system administrators can remotely view the text-based console on their remote machines from
anywhere and perform any task that does not require a GUI.
To activate SOL Support, follow the below procedures:
1. Click Remote Control from the Menu Bar.
2. Click Activate to activate SOL. Columns and Rows can be configured separately by changing the input
field.
3. Click Deactivate to deactivate SOL.
Chapter 5. Advanced configurations 49
Image Redirection
This page is used to configure the images into BMC for redirection. This can be done either by uploading an
image into BMC, Local Media or by mounting the image from the remote system, Remote Media.
Note: VMedia privilege only restricts initiating or starting media redirection. If a device is already redirected
and attached to the host, then in host it will be visible as normal device. Hence it will be accessible to all the
KVM sessions, which includes KVM Privilege only sessions as well.
Media Redirection General Settings
General Settings
Description
Local Media Support
Enable or disable Local Media support.
Remote Media Support Enable or disable Remote Media support. If it is selected, the
following remote media types will be displayed.
Mount CD/DVD*
Mount Hard disk
Note: *If the share type is HTTP or HTTPS, the checked status of the
option “Mount CD/DVD” cannot be kept after refreshing, but it will not
affect the functionality
On selecting the individual media types, its respective configurations will be displayed. You can configure
different settings for different remote media types.
Settings
Description
Share Type for CD/DVD Share Type of the remote media server, NFS, Samba (CIFS), HTTPS,
and HTTP are supported.
Notes: Remote media HTTP/HTTPS support limitations are as
follows:
Only CD Image redirection is supported.
Only one CD/DVD Instance is supported.
Same settings for Harddisk Images Enable or disable to select same media type data configurations for all
the remote media types.
Mount Harddisk Enable or disable to mount hard disk.
Server Address for Harddisk Images Address of the server where the remote media images are stored.
Path in server
Source path to the Remote media images.
Share Type for Harddisk Select share type for hard disk either NFS or CIFS.
Domain Name, Username, and Password
If share type is Samba (CIFS), then enter user credentials to
authenticate on the server.
Save Save the settings.
VMedia Instance Settings
To configure VMedia Instance:
1. Select the number of CD/DVD devices, Hard disk devices and Remote KVM CD/DVD and Hard disk
Devices from respective drop-down list boxes.
50
ThinkStation BMC remote management console User Guide
Note: Maximum of four devices can be added in CD/DVD and hard disk drives.
2. Check Power Save Mode to enable or disable the virtual USB devices visibility in the host.
3. Click Save to save the changes made.
Note: Virtual media configuration changes will restart all the media services. So, configuration changes
will be blocked when any active media redirection is present.
Active Redirections
Used to display the active redirected media, which are redirected via JViewer/VMAPP/ H5Viewer/LMedia/
RMedia/VMCLI. Information like media type, media instance, client type, image name, redirection status,
client IP will be displayed.
Settings
Description
Media Type
The type of media devices (CD/DVD) supported for active redirections
Media Instance The number of media devices supported for active redirections
Client Type The type of media devices (CD/DVD) supported for active redirections
Image Name The name of media devices supported image for active redirections
Redirection Status The status media for active redirections
Client IP The IP of the connected media devices (CD/DVD) supported for active
redirections
Note: Local or remote media connection will use loopback socket for communication. So “~” symbol will be
displayed for loopback IP (127.0.0.1 (or) ::1 ) in media session information page.
Local Images
This page displays the list of available images in the local media on BMC. You can replace or add new
images from here.
To configure the image, you need to enable Local Media support under Image Redirection Media
Redirection General Settings. Once you enable this option, the user can add the images and the added
images will be redirected to the host machine.
Notes:
Support maximum 2TB microSD card.
The microSD card is divided into at least 2 partitions and should be formatted as ext4/ext3/ext2 file
system. Place the image(s) to the partition 2.
To delete or add an image, you must have Administrator Privileges.
More than one image can be uploaded for each image type. The allocated size for local media upload is
determined by the size of partition 2. User cannot upload image size greater than 1GB. For example, if the
allocated size for partition 2 is 3GB, the user can upload multiple images to fill up the 3GB size, but each
upload image size should not exceed 1GB.
Support CD/DVD format: ISO9660, UDF(v1.02~v2.60).
Support CD/DVD media file type: (*.iso), (*.nrg).
For your reference, the following microSD cards have been tested compatible.
SanDisk microSD, SDHC, 16GB
Kingston microSD, SDXC, 64GB
Chapter 5. Advanced configurations 51
Compatible cards are not limited to the above list.
To configure local images:
Note: The Start Redirection button is active only for VMedia enabled users.
1. Click on the Local Images section.
2. Select a configured slot and click
to start the local media redirection. It is a toggle button, if the image
is successfully redirected, then click
to stop the local media redirection. If you want to pause the
Local media Redirection, click
.
3. To add an image, select a free slot and click
to upload a new image to the device. A pop-up screen
will be displayed, prompting you to select the image. Select the image and click OK to continue adding
the image.
4. To clear an image status, select an image and click
to clear image status from the device.
5. To delete an image, select a record and click
to delete the selected image. A popup message will be
displayed, prompting you to continue. Click OK to continue deleting the image.
Note: Redirection needs to be stopped to delete the image.
6. To refresh the image lists, click
to get the latest image lists.
7. To sync the image status, click
to sync the latest images’ status.
Remote Images
This page displays configured images on BMC. You can configure images of the remote media server.
To configure remote images:
1. To start or stop redirection and configure remote media images, click
and make sure Remote Media
Support is enabled.
Note: The Start Redirection button is active only for VMedia enabled users.
2. Select a configured slot and click
to start the remote media redirection. It is a toggle button, if the
image is successfully redirected, then click
to stop the remote media redirection. If you want to pause
the Remote media Redirection, click
.
Note: Redirection needs to be stopped to clear the image.
3. To clear an image status, select an image and click
(Clear icon) to clear image status from the device.
4. Click Refresh Image list to get latest image lists from the remote storage. The latest image names list
will be displayed in the Image Name drop-down list box.
5. Click Sync Image Status to get the image status from the remote storage. The latest image status will
be displayed in the Redirection Status list.
Maintenance
This maintenance group allows you to do maintenance tasks on the device.
Backup Configuration
Allow you to select the specific configuration items to be backed up.
To backup configuration:
52
ThinkStation BMC remote management console User Guide
1. Check Check All to back up all configuration items or check the configuration that needs to be backed
up.
Note: Network configurations are inter-related to IPMI, and hence by default IPMI will be selected
automatically when you select Network and Services to be backed up and vice versa.
2. Click Download to save the backup configuration file to the client system.
Note: During the backup process, the mechanism will parse and filter out the values of sensitive data related
to passwords.
BMC Recovery
Allow you to configure BMC recovery settings. The BMC Auto-Recovery is a mechanism to flash and boot
the recovery image when primary image in the SPI-ROM is corrupted or fails to boot. It will provide an
additional failure over mechanism for BMC firmware.
To configure BMC recovery:
Check or clear Force Recovery to start auto-recovery immediately at next reboot.
1. Enter the Boot Retry Count value.
2. Enter the Recovery Retry Count value.
3. Enter the Server Address to store firmware image.
4. Enter the Image Name.
Note: By default, the image name is mentioned as rom.ima.
5. Click Save to save the configured settings.
Notes:
The recovery image can be loaded from microSD card (partition 1). If failed, image will be recovered from
TFTP path.
The recovery image’s name in microSD card is restricted to “rom.ima”.
In order to perform BMC firmware recovery via microSD, partition table should be GPT label and partition
1 should have EXT filesystem. The Recovery image “rom.ima” should be in partition 1.
Firmware Image Location
Used to configure firmware image into the BMC.
To configure Firmware image location:
1. Select the Image Location Type (Web Upload during flash or TFTP Server).
2. If the protocol selected is TFTP, enter the IP address of the server in the TFTP Server Address field.
3. Enter the TFTP image name in the TFTP Image Name field.
4. Enter the TFTP retry count value in the TFTP Retry Count field.
5. Click Save to save the changes.
Firmware Information
Provide the active Firmware Information.
Chapter 5. Advanced configurations 53
Settings Description
Build Date
The build date of the active BMC image
Build Time The build time of the active BMC image
Firmware version
The Firmware version of the active BMC image
Firmware Update
Take you through the process of firmware upgradation. A reset of the box will automatically follow if the
upgrade is completed or cancelled. An option to Preserve All Configuration is available. Enable it if you
wish to preserve configured settings through the upgrade.
To update firmware:
1. Click Browse to select firmware image. The Firmware update undergoes the following steps:
a. Close all active client requests.
b. Prepare device for firmware upgrade.
c. Click Choose File to select your firmware image.
Note: A file upload pop-up will be displayed for http/https but in the case of TFTP files, the file is
automatically uploaded displaying the status of upload.
d. Click Start firmware update to upload the firmware image.
2. Click Preserve all Configuration to preserve all configurations if you prefer.
3. Click Proceed to Flash to start the firmware upload. A warning message will be displayed, prompting
you to proceed further and click OK to start the firmware upload.
4. Verify Firmware image:
In Section Based Firmware Update, you can configure the firmware image for section-based
flashing. Check the required sections and click Flash to Proceed to update the firmware.
If flashing is required for all images, select Full Flash.
If you select Version Compare Flash from web, the current and uploaded module versions, FMH
location, size will be compared.
If the modules differ in size and location, proceed with force firmware upgrade.
If all the module versions are the same, restart BMC by saying all the module versions are similar.
If only few module versions are differed, those modules will be flashed.
Note: Only selected sections of the firmware will be updated. Other sections are skipped. Before
starting flash operation, you are advised to verify the compatibility between image sections.
5. Click the Flash to Proceed again to flash firmware image.
6. Reset the image.
Notes:
The Firmware Update page will be disabled, and you will not be able to perform any other tasks until
firmware upgrade is completed and the device is rebooted. You can now follow the instructions
presented in the subsequent pages to successfully update the BMC card’s firmware. The device will
reset if update is canceled. The device will also reset upon successful completion of firmware update.
After resetting, the device IP may be changed, and you are supposed to use the latest IP to log in.
54
ThinkStation BMC remote management console User Guide
Preserve Configuration
Allow the user to configure the preserve configuration items, which will be used by the Restore factory
defaults to preserve the existing configuration without overwriting with defaults/ firmware update
configuration.
To preserve configuration:
1. Click Firmware Update or Preserve Configuration link to view the Firmware Update or Preserve
Configuration page accordingly.
2. Select the required preserve configuration items by either checking the appropriate check boxes or by
checking Check All.
3. Click Save to save the changes.
Settings
Description
SDR This contains the sensor data record information that is used in IPMI.
Dependency Configurations - NIL
FRU This contains the logical field replaceable unit data that are used by
IPMI.
Dependency Configurations - SDR
SEL This contains the system event logs that are being logged by the IPMI.
Dependency Configurations - IPMI
IPMI This contains the IPMI configurations, DCMI1.5 specification
parameters, the keys that are used to decrypt the passwords.
Dependency Configurations - NIL
Network
To save network settings related with IPMI (LAN IP or DHCP
configuration), select IPMI and Network simultaneously. After restore
configuration, the Network Configuration will be preserved
successfully.
Dependency Configurations - IPMI
NTP This contains the NTP dameon protocol configuration parameters, the
auto or manual network type protocols, the time to synchronize the
system clock, local time and time zone.
Dependency Configurations - IPMI
SNMP This contains the SNMP user configurations and SNMP users
privilege levels.
Dependency Configurations - NIL
SSH This contains the keyword argument pairs of configurations, the
private parts of the host keys, and the public parts of the host keys.
Dependency Configurations - NIL
KVM This contains the modes of media, the mouse mode configurations,
host machine physical keyboard language layout, the parameters of
video record file, the stunnel configuration, the user defined macro
from the JViewer, the image name and the remote machine
information.
Dependency Configurations - NIL
Chapter 5. Advanced configurations 55
Settings Description
Authentication
This contains the configurations related to authentication such as SSL
enable, timeout, RAC domain, AD type, open LDAP role group
information, PAM Order, user login information, and so on.
Dependency Configurations - NIL
Syslog This contains the system log configuration details to preserve different
event categories such as alert, critical, error notification and so on.
Dependency Configurations - NIL
Web This contains the firmware image location details to update firmware
configuration.
Dependency Configurations - NIL
Extlog
It preserves Extended SEL Log events.
Dependency Configurations - IPMI
Note: This support is feature based. If this feature is enabled, then
the Extlog option will be displayed in Preserve configuration.
Redfish Redfish preserves the Redis Database file.
Dependency Configurations - NIL
Note: This support is feature based. If this feature is enabled, then
the Redfish option will be displayed in Preserve configuration.
Restore Configuration
Allow you to restore the configuration files from the client system to the BMC.
To restore configuration:
1. Click Browse to select the configuration file that needs to be backed up and used to restore the
configuration when needed.
2. Click Save to restore the backup files. The Restore Configuration page will be displayed.
3. Click OK to upload the new configuration file and restore.
Note: Reset password after restoring configuration.
Restore Factory Defaults
Used to restore the factory defaults of the device firmware. This section lists the configuration items that will
be preserved during restore factory default configuration.
To restore factory defaults:
1. Click Preserve Configuration to redirect to the Preserve Configuration page, which is used to preserve
the particular configuration not to be overwritten by the default configuration.
2. Click Restore Factory Defaults to restore the factory defaults of the device firmware.
Note: To ensure BMC’s proper functionality, power cycle your computer after restoration.
56
ThinkStation BMC remote management console User Guide
System Administrator
To configure the System Administrator settings:
1. Check Enable User Access to enable user access for system administrator.
2. Check Change Password to change the user password. This action enables the Password fields.
3. Enter the new password in the Password field.
4. Enter the password in the Confirm Password field again.
5. Click Save to save the changes.
Chapter 5. Advanced configurations 57
58 ThinkStation BMC remote management console User Guide
Appendix A. Trademarks
Lenovo, Lenovo logo, ThinkStation, and ThinkStation logo are trademarks of Lenovo. Microsoft and
Windows are trademarks of the Microsoft group of companies. All other trademarks are the property of their
respective owners.
© Copyright Lenovo 2024 59
60 ThinkStation BMC remote management console User Guide